HGC702608 - Titan Controls Atlas 3 - Day/Night CO2 Monitor/Controller
Download Instructions Instruction Guides
Titan Controls - How to Operate Atlas 3

This quick video shows you how to properly set-up and operate your Atlas 3 Titan Controller.

Controls and monitors CO2 from 0 to 2000 parts per million (PPM). CO2 enrichment or CO2 exhaust features. Easy to set-up and operate. Enclosure resists dust, rust and moisture. 5 Amps maximum/120 Volts/60 Hz.
 

Related Products:
Titan Controls Atlas 3

The Atlas 3 is easy to set up and simple to use. It controls and monitors CO2 from 400 to 5000 parts per million (PPM) and offers CO2 enrichment or CO2 exhaust features. Plastic enclosure resists dust and moisture. Another innovative product brought to you by Titan Controls!

Related Products:

Questions for Titan Controls® Atlas® 3 - Day/Night CO2 Monitor/Controller

No questions have been asked about this product yet.
Q: {{q.Question}}
A: {{q.Answer}}
{{q.VoteCount}} people found this helpful {{q.VoteCount}} person found this helpful
Did you find this question helpful?

Couldn't find an answer?

Ask your question here.
Providing an email will allow for a one-time alert when your question has been answered.
Thank you for submitting your question. Check back soon to receive an answer. You will receive an email when one of our customer service representatives has answered your question.
HGC702608 - Titan Controls Atlas 3 - Day/Night CO2 Monitor/Controller
  EACH CASE PALLET
Upc: 847127000908 10847127000905 20847127000902
Quantity: 16 256
Volume (cf): 0.141 3.025 60.556
Dim Weight (in3/lb): 1.870 39.636 752.806
Weight (lb): 5.000 35.000 538.000
Length (in): 4.500 21.500 48.000
Width (in): 10.500 20.500 40.000
Height (in): 5.500 12.500 54.500
Caution: Sulphur vaporization can damage your controller!
To protect your controller, it is important to disconnect and cover the Atlas 3 by wrapping with a plastic bag OR remove the controller from the grow area while using sulphur vaporizers in your grow room. Titan Controls can analyze and detect CO2 components that have been contaminated and damaged by sulphur vaporization. We reserve the right to not repair these defective units under warranty, however we can repair and return your Atlas 3 for a fee, if you would like.
Does my Titan controller need to be calibrated?
No, your controller has been factory calibrated and is ready for service when you take it out of the box. Each unit will provide years of use and will maintain its settings without any further changes required. Please contact us if you think that your calibration is not correct and we can help you out.
My CO2 monitor/controller is reading really high all the time. What's wrong with it?
We hear this a lot. The main issue is the 2000 ppm of CO2 we exhale when we're breathing. If you're in your room and you see that the ppm is high, leave the area for an hour or so and turn off your CO2 source, then peek your head in and check the reading, it should be reading under 1000 ppm mattering on how well your room is sealed. After observing your CO2 Monitor/Controller for awhile, you'll start to see what your normal ppm level is in your room. The normal outdoor ppm is 400 ppm to 600 ppm based on where you live (city vs. rural).
Should I run my CO2 at night?
No, you shouldn't. Plants photosynthesize CO2 only during the daylight hours. At night, the plants expire CO2 and have no use for CO2. So, save yourself some money and only dose CO2 during daylight hours when it does the most good for the plants.
I'm getting "Er.1" showing on my Atlas 3 LCD display. What does it mean?
This is 'Error Code 1' for the Atlas 3. This is a problem with the CO2 sensor in the controller. To fix it, just turn off the power, wait five seconds and then reactivate the controller. This should take care of it. If not, give us a call at 888-808-4826 and we'll help you out.
I'm getting "Er.8" showing alternately with the sensor values on my Atlas 3 LCD display. What does it mean?
This is 'Error Code 8' for the Atlas 3. This is a memory corruption problem and all your preferred settings will be reset to the default factory settings. To fix it, re-enter your preferred settings and this should take care of it. If not, give us a call at 888-808-4826 and we'll help you out.
What is the maximum square feet that the CO2 sensor is most effective?
The maximum square footage that is recommended for use of the sensor is 400 square feet. It may be used in larger areas, however the reaction time for the controller will be extended.
{{replacementPartsListModel.ParentPartId}} - {{replacementPartsListModel.ParentPartName}}